Function
Specify the X and Y coordinates where the printer can home the Z axis without interfering with the partially-completed print.
Restrictions
- Not shown when Has Hardware Leveling is enabled as G29 procedures could interfere with a partially-completed print.
- Not shown when Home Z Max is enabled as homing up would not interfere with a partially-completed print.
Parameters
- millimeters (mm)
Example(s)
mm
In this example, the best coordinates on the X and Y axes for the printer to home the Z axis are 185, 190.