Difference between revisions of "CONTROLS/Temperature"

From MatterControl Manual
Jump to: navigation, search
Line 1: Line 1:
{{DISPLAYTITLE:Temperature}}[[File:Tempcontrol.png|center]]
+
__NOTOC__{{DISPLAYTITLE:Temperature}}[[File:Temperature-ss.png|right|framed|<center>The 'Temperature' section of the Controls pane.</center>]]
  
The printer's bed and extruder can be heated manually by typing in a value in the entry box. There are also presets for the extruder and bed temperatures. For the extruder temperature, the PLA and ABS presets are 190ºC and 220ºC respectively. For the bed temperature, the PLA and ABS presets are 70ºC and 130ºC respectively. The Target and Actual temperatures of the extruder are displayed to the left of the box. The current temperatures of the bed and extruder are displayed with two white icons at the top-right corner of the interface.
+
The printer's extruder and heated bed (if present) can be heated manually by entering a value in the related field.  
 +
 
 +
Presets for the extruder and bed temperatures are available.  
 +
<br clear=all>
 +
== Extruder Temperature ==
 +
 
 +
Controls the temperature of the nozzle. If multiple extruders are present and [[Slice Settings/Printer/Features/Hardware/Extruder Count|specified]], a section appears for each one.
 +
 
 +
=== Actual ===
 +
 
 +
The actual temperature of the nozzle, in degrees Celsius.
 +
 
 +
=== Target ===
 +
 
 +
The intended temperature of the nozzle, in degrees Celsius. The printer will attempt to reach this value automatically when the difference of the Actual and Target Temperatures is more than 0.5°C, whether it is higher or lower.
 +
 
 +
To set a value: click the box, enter a value, then click the 'SET' button or hit enter.
 +
 
 +
=== OFF ===
 +
 
 +
Turn the extruder heater off.
 +
 
 +
=== PREHEAT ===
 +
 
 +
Sets the Target temperature to the current [[Slice Settings/Filament/Filament/Extruder Temperatures/Extruder Temperature|Extruder Temperature]] as set in Slice Settings.
 +
 
 +
== Bed Temperature ==
 +
 
 +
Controls the temperature of the heated bed.
 +
 
 +
=== Actual ===
 +
 
 +
The actual temperature of the bed, in degrees Celsius.
 +
 
 +
=== Target ===
 +
 
 +
The intended temperature of the bed, in degrees Celsius. The printer will attempt to reach this value automatically, whether it is higher or lower than the Actual temperature.
 +
 
 +
To set a value: click the box, enter a value, then click the 'SET' button or hit enter.
 +
 
 +
=== OFF ===
 +
 
 +
Turn the bed heater off.
 +
 
 +
=== PREHEAT ===
 +
 
 +
Sets the Target temperature to the current [[Slice Settings/Filament/Filament/Bed Temperatures/Bed Temperature|Bed Temperature]] as set in Slice Settings.
 +
 
 +
== Temperature Shortcut Presets ==
 +
 
 +
[[File:Temperature Shortcut Presets-ss.png|right]]Temperature Shortcut Presets are available for both the Extruder Temperature(s) and the Bed Temperature. Click the pencil icon ([[File:Pencil-edit.png]]) to the right of the name to open the respective window.
 +
 
 +
Up to three presets can be saved. They will be listed in order of temperature, from lowest to highest.
 +
 
 +
[[File:Temperature Presets-Edit.png|framed|none|<center>Click the pencil icon to open the presets window.</center>]]
 +
 
 +
=== Label ===
 +
 
 +
Give the preset a unique name.
 +
 
 +
=== Temp (C) ===
 +
 
 +
The temperature to which the preset will cause the extruder or bed to heat.
 +
 
 +
=== Max Temp. ===
 +
 
 +
Something
 +
 
 +
[[File:Temperature-Presets-ss.png|none|framed|<center>The 'ABS' example preset in use.</center>]]
  
 
[[Category:Features]]
 
[[Category:Features]]
 
[[Category:Incomplete]]
 
[[Category:Incomplete]]
 +
[[Category:Controls]]

Revision as of 10:36, 14 January 2016

The 'Temperature' section of the Controls pane.

The printer's extruder and heated bed (if present) can be heated manually by entering a value in the related field.

Presets for the extruder and bed temperatures are available.

Extruder Temperature

Controls the temperature of the nozzle. If multiple extruders are present and specified, a section appears for each one.

Actual

The actual temperature of the nozzle, in degrees Celsius.

Target

The intended temperature of the nozzle, in degrees Celsius. The printer will attempt to reach this value automatically when the difference of the Actual and Target Temperatures is more than 0.5°C, whether it is higher or lower.

To set a value: click the box, enter a value, then click the 'SET' button or hit enter.

OFF

Turn the extruder heater off.

PREHEAT

Sets the Target temperature to the current Extruder Temperature as set in Slice Settings.

Bed Temperature

Controls the temperature of the heated bed.

Actual

The actual temperature of the bed, in degrees Celsius.

Target

The intended temperature of the bed, in degrees Celsius. The printer will attempt to reach this value automatically, whether it is higher or lower than the Actual temperature.

To set a value: click the box, enter a value, then click the 'SET' button or hit enter.

OFF

Turn the bed heater off.

PREHEAT

Sets the Target temperature to the current Bed Temperature as set in Slice Settings.

Temperature Shortcut Presets

Temperature Shortcut Presets-ss.png
Temperature Shortcut Presets are available for both the Extruder Temperature(s) and the Bed Temperature. Click the pencil icon (Pencil-edit.png) to the right of the name to open the respective window.

Up to three presets can be saved. They will be listed in order of temperature, from lowest to highest.

Click the pencil icon to open the presets window.

Label

Give the preset a unique name.

Temp (C)

The temperature to which the preset will cause the extruder or bed to heat.

Max Temp.

Something

The 'ABS' example preset in use.